Blaze Audio PowerZone Connect 4008 UNI 8x500W 4 Ohm 4x1000W 100V 16 Ohm Blaze Audio PowerZone Connect 4008 UNI 8x500W 4 Ohm 4x1000W 100V 16 Ohm Blaze Audio PowerZone Connect 4008 UNI 8x500W 4 Ohm 4x1000W 100V 16 Ohm

Blaze Audio PowerZone Connect 4008 UNI

8x500W 4 Ohm 4x1000W 100V 16 Ohm

Varenr: 132896
Alt. varenr: LBX-888-010
✉ Send meg mail når varen er på lager
BeskrivelseEkstern InfoTeknisk info
Beskrivelse

Levering estimert fra primo juni 2024

The PowerZone Connect 4008 is a compact DSP amplifier in full rack, 2U format. It’s network-connected, giving wired or wireless access to the PowerZone Control web app’s system setup and audio configuration menu. From here you can manage inputs/outputs, control sound zones and access professional tuning settings – all helping achieve impressive sound in the shortest time possible.

It can drive both conventional low impedance (4O to 16O) loudspeakers and constant voltage (70V/100V) transformer coupled loudspeakers. With four analogue inputs, and one stereo digital input, it has flexible output options – 8 x 500W in Lo-Z mode and 4 x 1000W in Hi-Z mode. Automatic power sharing technology enables 1000W to be shared proportionately between each pair of Lo-Z outputs. 

  • Full matrix DSP amplifier with configuration and control via the simple WebApp
  • Flexible power output with 8 x 500W / 4 x 1000W and power sharing technology
  • Route any input to any output channel – create sound Zones in minutes
  • Ultra-compact form factor means it can be installed in spaces where others cannot
  • Powered by Pascal UMAC™ Class-D technology

 

Total System Power 4000 W
Output Power @ 4 O 8 x 500 W
Output Power @ 70/100V* 4 x 1000 W
Powershare (up to)
Across all channels**4 x 1000 W
Power Consumption 2500W
Dimensions 90 x 483 x 413 mm
Weight 11,54kg

 

Output Circuitry UMAC™ Class D - full bandwidth PWM modulator with ultra-low distortion
Output Voltage 70Vp / 140Vpp (unloaded) // Bridged 140Vp / 280 Vpp (unloaded)
Signal To Noise-Ratio >106dB (A-weighted, 20Hz-20kHz, 8O load)
THD+N (typical) < 0.05% (20Hz-20kHz, 8O load, 3dB below rated power)
Frequency Response 20Hz-20kHz (+0/-0.25dB (8O load, 3dB below rated power)
Protection Circuits Short circuit -, DC -, Undervoltage -, Temperature - and Overload protection
Power Supply UREC™ universal mains switch mode power supply with Power Factor Correction (PFC) and standby converter
Operating temperature 0-40°C
Operating Voltage/Frequency Universal Mains, 100V-240V, 50Hz-60Hz
Standby Consumption < 0.5W

 

 